Sichuan Rongteng automation equipment Co., Ltd. is specialized in the R&D, design and production of gas powered generating units for multi power section and multi industry applications. The power of single unit ranges from 250KW to 300kW, and the power generation of 0.5MW ~32mW and above can be realized. Any combination of parallel modes can meet different gas power generation requirements.
The series of gas generator set products and solutions developed by the company have been widely used in petroleum, natural gas, electric power, chemical industry, railway and other fields, and are exported to the international markets.
Special note:
- High reliability gas engine
- Imported brand generator
- Imported unit controller system
- The unit has strong adaptability: it can adapt to the ambient temperature of -25 ~ 45 ℃ and the gas concentration with 55% ~ 100% methane content.
- Advanced engine control system: ignition control, knock control, speed regulation control, air-fuel ratio control, cylinder temperature control and unit protection control.
- Double cooling fans can increase the heat dissipation of the unit and improve the power generation efficiency of the unit.
1. The technical parameters in this document are based on natural gas with low calorific value of 32MJ/Nm3, which meet the standard conditions of ISO8528/1, /ISO3046/1 and BS5514/1.
2. Technical data are measured under standard conditions:
Absolute atmospheric pressure: 100kPa
Ambient temperature: 25℃
Relative air humidity: 30%
3, Adapt to DIN standard ISO 3046/1 rating under environmental conditions. The tolerance of rated fuel consumption is ±5%.
4. Dimensions and weights in this article apply only to standard products and are subject to change. This document is only for reference, if you need to order, please refer to the technical documents provided by Sichuan Rongteng.
Unit power system
Introduction to power system |
|||
Generator set model |
RTF250N-41N |
Rated power |
250kW |
Engine model |
T12 |
Generator model |
LSA46.3 L10 |
Brand |
SINOTRUCK |
Brand |
Leroy Somer |
Engine form |
Turbocharging, lean combustion |
Power factor |
0.8(Lag) |
Cylinder bore × Stroke mm |
126×155 |
Electrical efficiency |
94.1% |
Single unit displacement |
11.596 |
Generating capacity |
325kVA |
Intake form |
Turbocharging, forced intercooling |
Damping coil |
100% Copper |
Rated power of engine |
280kW |
Connection mode |
Star |
Rated speed |
1500r/min |
Excitation mode |
Brushless |
Cooling mode |
Forced water cooling |
Phase number |
Three phase four wire |
Lubrication mode |
Pressure, splash lubrication |
Insulation class |
H |
OILT Engine-oil-Temperature |
≤105℃ |
Degree of protection |
IP23 |
AGC series control system
Introduction to control system |
|||
Control system model |
AGC Series |
Brand |
DEIF Denmark |
Main functions: open control system, touch screen, integrated engine control, detection, protection, alarm and communication. |
|||
² The unit control cabinet is a floor cabinet structure with a single control panel. The control cabinet is equipped with controllers, switches, various display instruments, adjustment buttons, unit protection indicator lights, emergency stop buttons, etc. to control and monitor the working conditions of the generator unit. ² The unit can realize one key control, automatic adjustment of air-fuel ratio, automatic control of power factor, automatic loading and unloading, etc. ² Engine detection: intake pressure, engine water temperature, engine oil temperature, battery voltage, unit speed, voltage, current, transient power, etc. ² Automatic paralleling and power distribution. ² It has the functions of independent operation and municipal electronic network connection. ² Overload protection, overcurrent, short circuit, Underfrequency, overfrequency, undervoltage, overvoltage, overspeed and other complete engine protection, and send out alarm signals. ² The unit has the functions of manual emergency stop and automatic emergency stop in case of accident ² Configure can communication interface |
|||
System characteristics |
|||
With the characteristics of high reliability, stability, high cost performance, compact appearance, multi-range and integration of all functions, the unit can be used to operate in the optimal fuel load state, reduce the operation cost and reduce harmful emissions; |
Standard protection function |
Standard control function |
|
Generator protection l 2 × Reverse power l 2 × overload l 4 × Overcurrent l 1 × Overvoltage l 1 × Undervoltage l 1 × Over / under frequency l 1 × Current imbalance |
Power control l RPM control (synchronization) l Power control (municipal electronic network connection) l Load distribution (independent) |
Voltage control l Voltage tracking (synchronous) l Voltage control (Independent) l Power factor control (municipal electronic network connection)
|
Lubrication control l Automatic oil filling system l Early warning monitoring |
Pump control l Cooling system
|
|
Bus / power protection l 1 × Overvoltage l 1 × Undervoltage l 1 × Over / under frequency l 1 × Phase sequence protection l 1 × ROCOF alarm |
Fan control l Machine room ventilation l Cooling fan
|
Valve control l Cooling system l Heating system
|
Engine protection l Various general or custom protection functions l Detection |
|
Contact:
Sichuan Rongteng Automation Equipment Co., Ltd.
Phone/WhatsApp/Wechat : +86 177 8117 4421 +86 138 8076 0589
Website: www.rtgastreat.com Email: info@rtgastreat.com
Address:No. 8, Section 2 of Tengfei Road, Shigao Subdistrict,Tianfu New Area, Meishan city, Sichuan China 620564
Post time: Dec-08-2023